Installation guide
Removing a Hard Disk
Replacing the Disk Drive
ARX®1000 Hardware Installation Guide A-3
Escape character is '^]'.
Username: admin
Password: acopia
prtlndA1k> enable
prtlndA1k# raid silence
prtlndA1k# ...
Replacing the Disk Drive
To replace the disk drive, slide it into the empty slot and tighten its two captive
screws. The screws should be at least finger tight for the drive to properly engage.
Incorporating the Disk into the RAID
To incorporate the disk into the RAID, use the raid rebuild command from priv-exec
mode:
raid rebuild {disk1 | disk2}
where disk1 | disk2 specifies the disk to rebuild. The top disk is disk1.
For example, the following command rebuilds the lower disk:
prtlndA1k# raid rebuild disk2
prtlndA1k# ...
Monitoring the Rebuild
A disk rebuild can take more than an hour. To monitor the progress of the rebuild, you
can use the
show chassis diskuse command to see a percentage-complete meter:
show chassis diskuse
The meter is a number in the
Rebuild Progress field, under Disk Details.
For example, the following command shows that the rebuild is 21% complete. The
rebuild progress is shown in bold: