User's Manual
44
• Automatic control – when connected to a transceiver with CAT capability, the amplier will track
the operating frequency, and will change bands accordingly.
• Even if not CAT connected, the amplier monitors the input signal frequency through the built-in
frequency counter and automatically switches bands.
• Remotely controlled by RS232 port.
• Takes care of itself during operation via continuously working protection circuits in all modes.
• The operator can monitor more than 10 parameters of the amplier in operation.
• Easy maintenance – detailed data (55 parameters) about each of the last 28 hard-fault protection
trips is stored in the amplier’s memory.
• Convenient for expeditions and eld operation due to the extremely compact and lightweight
construction and the built-in switching-mode power supply (SMPS) that operates with extended
mains voltage range of 93-265VAC (Output power reduced below 150VAC), with no internal
switch over. The consumed current is purely sinusoidal, Power Factor Corrected (PFC) and
inrush limited. This makes the operation from unstable mains and generators easy and trouble
free.
• Perfect electromagnetic compatibility (EMC) with both highly sensitive devices and the powerful
devices in the radio station (receivers, computers, other ampliers) exceeding the standard
EMC requirements due to the used PFC and built-in radio-frequency lters.
1-5. Safety considerations, explicit denitions
The ACOM 1200S linear amplier is a Class I apparatus regarding protection against electric shock, i.e.
the third grounding lead of its mains cord (colored yellow with two green stripes) and the grounding stud
on the rear panel, marked GND (Fig. 2-1), must be connected to the grounding system of the shack for
safe operation.
The ACOM 1200S amplier is designed to meet international safety standards and complies with the CE
electromagnetic compatibility requirements, as well as the FCC regulations.
This operating manual contains precautions, cautions, and warnings that MUST BE CОMPLIED TO
by the user to ensure safe operation and maintaining of the ACOM 1200S amplier in a safe working
condition.
PRECAUTIONS:
The EXPLICIT DEFINITIONS described below apply to this operating manual:
W A R N I N G notes call attention to a procedure which, if not correctly performed,
could result in personal injury or re hazard by electric shock or lightning.
C A U T I O N notes call attention to a procedure which, if not correctly performed, could result
in equipment damage, not only in the ACOM 1200S amplier.
N O T E notes call attention to a procedure which, if not correctly performed, could result in
inconvenience.