Owner's manual

14628 Central Ave,
Chino, CA 91710
tel:909.597.7588, fax:909.597.1939
© Copyright 2013 Acnodes, Inc.
All rights reserved. Product description and product specifications
are subject to change without notice. For latest product information,
please visit Acnodes web site at www.acnodes.com.
RPWQ 1190
1U 19” 1440x900 Rackmount CCTV Monitor
A larm
< 4 .2 > QD ALARM Con nec tion & Operation
3 Sensor Activated Alarm
The u nit is equipped w ith 4 alarm s ensor inputs. If any alarm is ac tiv ated:
¦ the built -in buzz er and the alarm output c ontrol relay contac t will be activated.
¦ the quad w ill s witch the corresponding channel indicator LED to blinking mode.
¦ a w arn ing mess age depending on di fferent models will be displayed as follows:
Quad output channel (#4)
LIVE output channel (#5)
Blinking A larm & T itle m essage on the
activated c han nel in quad screen
A larm
F ull screen display of the activated channel.
A lso display a blinking A larm m essage
Above m entioned alarm can be c leared by any of th e follow ing: 1. Connec ting the Alarm Res et In contact, p in #5, of the
fem ale ty pe 9 pin D -sub connec tor (#8) to G ND . 2. The Alarm D uration time elapses. 3. If the devic e is operated under
Sec urity Lock ON mo de, Pus h Lo ck button for 2 sec onds to disable the func tion then push any button in the front panel.
4 Video Lo ss Alarm
L oss of v ideo at any input is automatically detected by the dev ice. T he device will:
¦ A ctiv ate the built -in buzze r.
¦ S witch the c orrespondin g channel indic ato r LED to blinking m ode.
¦ Display warnin g me ssage on quad s creen:
Quad output channel (#4)
Video loss
B linking V ideo Loss & Title m es sage
on the activate d channel in quad
screen
¦ The warning m es sage and the buzz er c an be cleared
by pus hing Lock button (#2) for more than 4 sec onds if the
device is operated under Security loc k On mode, or pushing
any button on the front panel if the dev ic e is operated under
Security lock OFF mode.