RMWQ 8190
8U 19” 1440x900 Rackmount CCTV Monitor
}
}
}
}
< 4.3 > QD Remote Control Connection & Operation
2.3 The configuration of the status code for both normal and alarm operations:
There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation
modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the
unit.
BYTE 1 BYTE 2
START STOP START STOP
BYTE 1: Status code for normal operation modes
b7 b6 b5 b4 b3 b2 b1 b0
LOCK VCR SEQU QUAD CH4 CH3 CH2 CH1
Channel Select
1110 = CH1
1101 = CH2
1011 = CH3
0111 = CH4
Display Mode
0 = Quad screen display
1 = Full Screen display
Auto-sequencing mode
0 = Auto sequencing mode
1 = Quad or full screen mode
VCR mode
0 = VCR operation
1 = Live operation
Security Lock mode
0 = Security lock ON mode
1 = Security lock OFF mode
Menu Setup mode
00 = Menu setup mode