8U 19” 1440x900 Rackmount CCTV Monitor
A larm
< 4.2 > QD ALARM Con nec tion & Operation
3 Sensor Activated Alarm
The u nit is equipped with 4 alarm s ensor inputs. If any alarm is ac tivated:
¦ the built -in buzz er and the alarm output c ontrol relay contac t will be activated.
¦ the quad w ill s witch the corresponding c hannel indicator LED to blinking mode.
¦ a warn ing mess age depending on di fferent models will be displayed as follow s:
Quad output channel (#4)
LIVE output channel (#5)
Blinking A larm & T itle m essage on the
activated c han nel in quad screen
A larm
F ull screen display of the activated channel .
A lso display a blinking A larm m essage
Above m entioned alarm can be c leared by any of th e following: 1. Connec ting the Alarm Res et In contac t, p in #5, of the
fem ale type 9 pin D -sub connec tor (#8) to G ND. 2. The Alarm D uration time elapses . 3. If the devic e is operated under
Sec urity Lock ON mo de, Pus h Lo ck button for 2 sec onds to dis able the func tion then push any button in the front panel.
4 Video Lo ss Alarm
L oss of v ideo at any input is automatically detected by the dev ice. The device w ill:
¦ A ctiv ate the built -in buzze r.
¦ S witch the c orrespondin g channel indicato r LED to blinking m ode.
¦ Display warnin g me ssage on quad s creen:
Quad output channel (#4)
Vi deo loss
B linking V ideo Loss & Title m es sage
on the activate d channel in quad
screen
¦ The warning mes sage and the buzz er c an be cleared
by pus hing Lock button (#2) for more than 4 sec onds if the
device is operated under Security loc k On mode, or pushing
any button on the front panel if the dev ice is operated under
Security lock OF F mode.