RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor User Manual RMWQ8190: 8U 19” 1440x900 Widescreen Industrial Rackmount CCTV Monitor 14628 Central Ave, Chino, CA 91710 tel:909.597.7588, fax:909.597.1939 © Copyright 2013 Acnodes, Inc. All rights reserved. Product description and product specifications are subject to change without notice. For latest product information, please visit Acnodes’ web site at www.acnodes.com.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor Legal Information First English printing, October 2002 Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. The information in this document is subject to change without notice. We are not liable for any injury or loss that r esults from the use of this equipment. Safety Instructions Please read all of these instructions carefully before you use the dev ice.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor Contents < Part. 1 > RMWQ 8190 1.1 1.2 1.3 Package Content Structure Diagram & Dimension Installation P.1 P.1 - 2 P.3 < Part. 2 > Specifications / OSD 2.1 2.2 Product Specifications On-screen Display Operation ( OSD ) P.4 - 5 P.6 < Part. 3 > Options 3.1 48V, 24V or 12VDC power P.7 < Part. 4 > Quad Display Connection & Operation 4.1 4.2 4.3 4.4 4.5 4.6 4.7 QD QD QD QD QD QD QD 14628 Central Ave, Chino, CA 91710 tel:909.597.7588, fax:909.597.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor Before Installation ¦ It is very important to mount the equipment in a suitable cabinet or on a stable surface. ¦ Make sure the place has a good ventilation, is out of direct sunlight, away from sources of excessive dust, dirt, heat, water, moisture and vibration. Unpacking The equipment comes with the standard parts shown in package content. Check and make sure they are included and in good condition.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < P art 1 > < 1.1 > Package Content RP -W 119QD u n it X 1 - 6ft V GA cable X 1 - P ower cord X 1 - M 6 screw, cage nut & c up washer X 8 T he above package content is on ly for the p ure mo del ( VGA o nly ). It varies with op tion s su ch as DC p owe r. < 1.2 > Structure D iagram 1 2 3 4 5 1 LCD panel 3 LCD OSD membrane 2 Installation Slide 4 Quad d isplay co ntrol membrane 5 Th umb Sc rew 14628 Central Ave, Chino, CA 91710 tel:909.597.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 1.2 > Dimension Front View UNIT : mm Side View 1mm = 0.03937 inch Top View Model Product Dimension (W x D x H) Packing Dimension (W x D x H) Net Weight Gross Weight RP-119QD series 445 x 650 x 44 mm 17.5 x 23.6 x 1.73" 595 x 860 x 140 mm 23.4 x 33.9 x 5.5” 12.5 kg 28 lb 18.5 kg 41 lb The weight is only for the pure models. It varies with accessories & options such as DC power. 14628 Central Ave, Chino, CA 91710 tel:909.597.7588, fax:909.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 1 .3 > In stalla tion - How to install Ins ta llatio n Slide s Step ¦ Insert the left and r ight rear m ounting brackets into the display drawe r. Step ¦ ¦ 1 2 M easure the depth of the front and rear m ounting r ails. Align each rear m ounting bracket to a suitable length. S tep 3 C om plete the installation ¦ Fix the display draw er into the r ack. M 6 screw, cage n ut & cup washer x 8 are provided.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < Part 2 > < 2.1 > Product Specifications LCD Panel Manufacturer Panel Size ( diagonal ) 19-inch Widescreen TFT color LCD Display pixel ( dots x lines ) 1440 x 900 Brightness ( typ. ) 250 Contrast Ratio ( typ. ) 1000:1 Color 16.7 M Viewing Angle ( L/R/U/D ) 80/80/80/80 Response Time ( ms ) 5 Dot pitch ( mm ) 0.2835 Display Area ( mm ) 408.24H x 255.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor Physical Specification Product ( W x D x H ) 445 x 650 x 44 mm 17.5 x 25.6 x 1.73 inch Packing ( W x D x H ) 595 x 860 x 140 mm 23.4 x 33.9 x 5.5 inch Applicable Format Net Weight 12.5 kgs / 28 lbs Gross Weight 16.
< 2.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < Part 3 > < 3.1 > Options : DC Power Model 12V 24V 48V Input voltage: 12-Volt 24-Volt 48-Volt Input range: 9 ~ 18V 18 ~ 36V 36 ~ 75V - No load 50 mA 50 mA 50 mA - Full load 4950 mA 2450 mA 1220 mA Output voltage: 12-Volt 12-Volt 12-Volt Output current: 4.16A 4.16A 4.
< Part 4 > < 4.1 > QD Connection 1. VCR in : This BNC connector is connected to video output from VCR/DVR. A pre-recorded quad screen signal from a tape can be played back through a VCR/DVR and displayed on the video output channels. Push the VCR button (#2) to switch the device to VCR Playback mode. 2. VCR out : This BNC connector is to be connected to the Video in from your VCR/DVR. It will only provide a quad screen video to ensure an un-interrupted video recording for all four cameras.
< 4.2 > QD ALARM Connection & Operation 1. ALARM I/O : This female type 9 pin D-sub connector is used for alarm sensor input and alarm output control connections. It provides Normal Open and Normal Close contacts for alarm out control.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 4 .2 > QD ALARM Con nec tion & Operation 3 Sen sor Activated Alarm The u nit is equipped with 4 alarm s ensor inputs. If any alarm is ac tiv ated: ¦ ¦ ¦ the built-in buzz er and the alarm output c ontrol relay contac t will be activated. the quad will s witch the corresponding c hannel indicator LED to blinking mode.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 4.3 > QD Remote Control Connection & Operation Rear Panel IN hi- z 1 23 4 RS-232 OUT dc 12V, 1amp ALARM I/O monitor vcr 75 RS-232 Cable Wire Computer 14628 Central Ave, Chino, CA 91710 tel:909.597.7588, fax:909.597.1939 Remote Keypad © Copyright 2013 Acnodes, Inc. All rights reserved. Product description and product specifications are subject to change without notice. For latest product information, please visit Acnodes’ web site at www.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 4.3 > QD Remote Control Connection & Operation The device can be controlled via the male type 9 pin D-sub/RS-232 connector to a computer using ASCII code. 1.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 4.3 > QD Remote Control Connection & Operation *1. In order to control the device to operate in Zoom mode, the computer has to first send command code ” to switch the signal source from camera to VCR/DVR, at this time the device will automatically zoom channel 1 video from VCR/DVR to full screen. User can then input a corresponding channel code to zoom any other specific channel.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 4.3 > QD Remote Control Connection & Operation 2.3 The configuration of the status code for both normal and alarm operations: There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the unit.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 4.3 > QD Remote Control Connection & Operation BYTE 2: Status code for alarm operations: The first 4 bits show the sensor activated alarm status of each channel; next 4 bits show the video loss alarm status of each channel. The digit “1” means alarm event is detected, and “0” means no alarm event is detected.
< 4.4 > QD OSD Operation 3 1 Quad Display Control VC R SEQ < 2 4 < < Setup > 5 1 Lock: Security locks out button. Push this button for 2 seconds to enable control panel lock out function. Push this button again for 2 seconds to disable the function. 2 VCR: Push this button to enter into VCR Playback/Zoom operation. In this mode, the output video is displaying the video signal from VCR.
< 4.5 > QD On-screen Menu Right after the unit is turned on, The monitor will display the last setting on the Setup Menu. 1. Page 1 of the Setup Menu - Display Setting Push Setup buttons (#1, #2) simultaneously to display the Setup Menu on the screen. There are total two pages in the Setup Menu. Page 1 is used to program TIME, DATE, and camera TITLE. Page 2 is used to program Alarm Operations. Under this mode, channel selection buttons (#5) on the front panel are used for cursor control and text selection.
< 4.5 > QD On-screen Menu 2 Page 2 of the setup menu- Alarm Setting Push Setup buttons (#1, #2) simultaneously and push (#1) button again to display page 2 of the setup menu on the screen. This Alarm Setting menu is used to set the desired alarm configuration like sensor type, sensor sensitivity, alarm hold duration, and buzzer. ALARM SETTING CH SENSOR TYPE 1 OPEN NO 2 OPEN NO 3 OPEN NO 4 OPEN NO SENSITIVITY: DURATION: BUZZER: V-LOSS ALARM: V-LOSS RELAY: STATUS ON ON ON ON 0.3 S 30 S ON ON OFF 2.
RMWQ 8190 8U 19” 1440x900 Rackmount CCTV Monitor < 4.5 > QD On-screen Menu 4: The setup menu can be reset to factory setting by pushing the Setup buttons (#1, #2) and power on the quad simultaneously.
< 4.6 > QD VCR Operation Zoom on VCR playback operation: Push VCR button (#2) to ON will switch the device to VCR playback mode. Under this mode, if the device is on quad display mode, a pr-recorded quad display video in the tape will be shown on the screen. If the device is in Full screen display mode, push any channel select buttons (#5) will select and expand the corresponding quadrants of the prerecorded video to full screen display. < 4.