User`s manual
8
KOOLMASTER PP20-VS2 rev.00
KOOLMASTER PP20-VS2
3.2. Parameter Adjustment
Use the navigation buttons to select the
desired parameter on the main screen. A
parameter that can be modified blinks when
it is selected; non-blinking parameters cannot
be changed.
3.3. Language Selection
The user interface of the controller can be
displayed in multiple languages. Follow these
steps to change the language selection:
Select:1.
Current Conditions (Main Menu)
More [Otros]
Español [English]
User Settings
Monitoring
Program
Selection
Setup
Time/Date
Español
Use to navigate
The controller automatically changes the 2.
language display.
Press and hold the main menu button
for 5 seconds to switch the language
selection.
3.4. LED Meaning
LED MEANING
CLEAN MODE Solid LED: Clean mode is active.
ALARM Solid LED: An alarm condition is active.
A corrective action is required.
Flashing LED: An alarm condition occurred
but no longer exists.
STIR FAN Solid LED: The stir fan output is active.
TUNNEL 2 Open Solid LED: Tunnel door #2 is opening.
Close Solid LED: Tunnel door #2 is closing.
TUNNEL 1 Open Solid LED: Tunnel door #1 is opening.
Close Solid LED: Tunnel door #1 is closing.
CURTAIN 2 Open Solid LED: Natural ventilation curtain #2 is opening.
Close Solid LED: Natural ventilation curtain #2 is closing.
CURTAIN 1 Open Solid LED: Natural ventilation curtain #1 is opening.
Close Solid LED: Natural ventilation curtain #1 is closing.
INLET 2 Open Solid LED: Inlet #2 is opening.
Flashing LED: The controller opens inlet #2 to reset the
actuator's position.
Close Solid LED: Inlet #2 is closing.
Flashing LED: The controller closes inlet #2 to reset the
actuator's position.
INLET 1 Open Solid LED: Inlet #1 is opening.
Flashing LED: The controller opens inlet #1 to reset the
actuator's position.
Close Solid LED: Inlet #1 is closing.
Flashing LED: The controller closes inlet #1 to reset the
actuator's position.
STAGES 1-12 Solid LED: Fan stage #x is active.
MINIMUM VENTILATION Solid LED: On Time of the minimum ventilation timer.
Flashing LED: Off Time of the minimum ventilation timer.
HEATERS 1-3 Solid LED: Heating output #x is active.
MISTING Solid LED: On Time of the misting timer.
Flashing LED: Off Time of the misting timer.
SOAKING Solid LED: On Time of the soaking timer.
Flashing LED: Off Time of the soaking timer.
KOOL-CEL® Solid LED: On Time of the Kool-Cel® timer.
Flashing LED: Off Time of the Kool-Cel® timer.
0-10V 1-2 Solid LED: 0-10V output #x is active.
CLOCK 1-2 Solid LED: Clock output #x is active.