User`s manual
10
KOOLMASTER PP20-VS2 rev.00
KOOLMASTER PP20-VS2
Program Settings
Use to navigate
Program 2 above day: 10
Program 3 above day: 20
Program 2 above Out T: 50.0
Program 3 above Out T: 75.0
Show Settings : Program 1
[ or ]
Running Prog.: Program 1
Set the following parameters:2.
Program #x above — If the program switch
is based on the animal age, select the day at
which programs 2 and 3 start; if the switch
is based on the outside temperature, select
the outside temperature above which each
program starts. Note that program 1 is au-
tomatically used when the animal age (or
outside temperature) is lower than the value
defined for programs 2 and 3.
Show settings of — Even when a program is
running you can still display parameter set-
tings of other programs without changing the
program in use. Select the desired program
to be displayed on screen. *Only the programs
that are enabled in the Installation Setup are avail-
able (see sec. 4.5).
Running program — This message is shown
when the program selection is made manu-
ally (i.e., it is not selected as a function of
the day and/or outside temperature). Select
the running program. *Only programs that are
enabled in the Installation Setup are available (see
sec. 4.5).
The day number refers to the animal age.
4.3.2. Copying & Pasting Programs
Use the copy-paste function to duplicate all
parameter settings associated to a program
onto another program. This avoids repeating the
same programming sequence several times.
Select:1.
Current Conditions (Main Menu)
Setup *
Copy/Paste
* A password may be required to access this menu.
Program Settings
Copy From: Program 1
Copy to: Program 2
Confirm? No
Set the following parameters:2.
Co py F ro m — Select the source program. The
one that will be duplicated.
Copy to — Select the target program. The
one on which the copied program will be
pasted.
Once a different source and target 3.
programs are selected, the message “Con-
firm?” is displayed. Select “Yes” to start the
program duplication. The message “ Copy
in progress” is displayed. Wait until the data
transfer is over.
4.4. Measuring Units
Select:1.
Current Conditions (Main Menu)
Setup *
User
Units
* A password may be required to access this menu.
Unit Selection
Time Display AM/PM
Temperature Deg F
Water Liter
Static Pressure “WC
Select the proper measuring units:2.
Time display — AM/PM / 24 hours;
Temperature units — Celsius (Deg C) or
Fahrenheit (Deg F).
Water — Gallons / Liters
Static Pressure — Inches of water (“WC) or
Pascal (Pa).
Measuring units are common to all pro-
grams of the controller.