5
2)Control Box(See Supplement CControl Box)
12 Function Key
1.Unit--To change measuring unit by IN(inch
2
)DM (decimeter
2
)FT (feet
2
)M
2
(meter
2
).
2.Set--To set the percentage of compensation and the number of batch set.
CMPST ==>Compensation. To recover the loss in the measuring, the fair
compensation is needed.
BCHST==>Batch set. For the advantage to package, the number of BCHST is
adjustable.
Note: The data that set previously will be reserved till the “Format Button” is pushed.
3.Mode--For display batch total and grand total.
BTT (Batch Total)==>The total number of batches. And these batches must be
measured in the same unit.
GTT (Grand Total)==>The total area that measured in one batch.
Note
When the unit is changed (ex. IN==>DM or FT==>IN), the total number will be
clear, and count again from 0.
4.R/F (Round off/Four Digits): For decide the calculation.
Round Off==>Value are rounded off (01234 cut off56789 are round
up).
Four==>In this case, the display will show the value with four digits.
According to the different unit, the digits will be different, too.
IN Case: In round off mode, the value will be round off, so the last digit will always be