Specifications

8F
3. Lamp
MSD 250/2 GY 9.5 (IR-7S/7B/IR-5C) CDM 150W ( IR-6SD/ IR-6BD )
ELC 24V 250W (IR-6S/IR-6B/IR-5S/IR-5B/ IR-4C/IS-6S/IS-6B/IS-4/IS-3)
Diagram for lamp changing
Because of its high internal pressure, there might be a
risk that the Discharge lamp would explode during
operation. The lamp emits intense UV radiation which
is harmful to the eyes and skin. The high luminance of
the arc can cause severe damage to the retina if looks
directly at t he lamp.
1. Always switch off the main supply and never handle
the lamp or luminaries when is hot.
2. Do not t ouch the bulb with bare hands. If t his
happens, clean the lamp with denatured alcohol and
wipe it with a lint f ree cloth before installation.
3. The lamp generates UV radiation. Never operate the
lamp without appropriate shielding.
4. When burning, the lamp operates at high pressure and
there is a slight risk of arc tube rupture. The risk
increases with age, temperature and improper
handling of the lamp. Do not use the lamp any
longer than its specified life.
Make sure the lamp is located in the center of the
reflector for the best spot.
IR-7S/7B/5C ( IR-5C is a 5 channel color changer )
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
MSD 250/2
CDM 150W
ELC 24V 250W
ELC 24V 250W