Specifications
80
Tech Support: 855-ONE-ZURN
www.zurn.com
Model ZW1070
• 3/8”, 1/2”, 3/4”, 1”
• Thermostatic mixing valve (anti-scald)
• Certified to ASSE standard 1016 (1996 edition) and 1070
• CSA
®
Certified
• Point of use application
• Set temp accuracy ±3°F
• Final safe temperature range of 95° – 115°F
• Integral check valves and stainless steel strainers
(no strainer in 38-ZW1017 Comp)
• Rough chrome plated
• Flow capacity ~ 10 gpm @ 45 psi pressure loss
Model ZW1070 Supplied with three FNPT tailpieces
and union nuts
Model ZW1070C Supplied with three female copper
sweat tailpieces and union nuts
Model ZW1070COMP Supplied with three compression
tailpieces and union nuts
Model ZW1070CPVC Supplied with three female CPVC
tailpieces and union nuts
OptionsTypical Installation Features
The Wilkins Model ZW1070 Aqua-Gard thermostatic mixing valve is designed to be installed at the
point of use to assist in the prevention of scalding. The valve’s extremely rapid response rate makes
it most suitable for installation at plumbing fixtures and appliances for the final control of water tem-
perature. The ZW1070 is ASSE 1016 and ASSE 1070 listed for point of use and will mix hot and cold
water from the distribution system to a final safer temperature of 95-115°F (35-46°C). Multiple end
configurations make this valve suitable for all residential and commercial installations.
The device is designed to be installed at a single outlet. It may be used to supply individual outlets when there is sufficient supply pres-
sure. It is suggested to use ball valves on the hot and cold inlet supplies.
Applications
MIXED
C
H
H
C
C
H
C
H
MIXED
Sensor Faucet
Model ZW1070M Supplied with three MNPT tailpieces and
union nuts
Model ZW1070PEX Supplied with three male PEX tailpieces and
union nuts
For Additional Information, reference WK-AG catalog or visit
our web site.
COLD & MIXED
SUPPLY USE
MIXED ONLY
SUPPLY USE
Thermostatic Mixing Valves