Typical InstallationX Ref
Backflow Preventer for Vending Machine Water Supply
Model 740
Features Applications
• 3/8”
• SAE J513 flare fitting threads inlet and outlet
• Designed for installation in vending machine water supply lines to pre-
vent backflow of carbon dioxide and carbonated water into the potable
supply
• Pressure rated to 150 psi
• Maximum temperature 130°F
• Consists of two spring loaded check valves with an atmospheric vent
located between the two checks
• Quick acting check valves prevent unnecessary vent discharge
• Manufactured with 300 series stainless steel
• Silicon rubber check valve discs
• Stainless steel springs
• Stainless steel strainer screen provided on the inlet to prevent check
fouling due to debris in the supply water line
• ASSE
®
Listed 1022
• California AB 1953 compliant
For Additional Information, reference WK-BPC catalog or visit
our web site.
Designed for installation on carbonated beverage dispensing systems, as well as non-carbonat-
ed systems, to prevent carbon dioxide (CO ) gas or carbonated water from coming in contact
with copper potable water supply line. The 740’s stainless steel construction ensures superior
corrosion resistance for increased longevity.
The Model 740 can be installed in the horizontal or
vertical position. Under certain conditions the Model
740 may discharge water from the vent port. Provisions
must be made to ensure that discharge will not damage
surrounding property or equipment. Copper tubing shall
not be used downstream of the Model 740.
2
CO
Gas
Carbonator
Carbonated
Beverage
Dispenser
Backflow Preventer
Model 740
Water
Supply
Filter
Pump
Safe Drain
Beverage
Dispenser
Supply
Water
Backflow Preventer
Model 740
Safe Drain
Carbonated Beverage System
Non-Carbonated Beverage System
2
CO
Gas
Carbonator
Carbonated
Beverage
Dispenser
Backflow Preventer
Model 740
Water
Supply
Filter
Pump
Safe Drain
Beverage
Dispenser
Supply
Water
Backflow Preventer
Model 740
Safe Drain
Carbonated Beverage System
Non-Carbonated Beverage System
WILKINS WATTS CONBRACO
740 SD-3, 9BD 4C-100
Backflow Preventers