Specifications

41
Tech Support: 855-ONE-ZURN
www.zurn.com
OptionsTypical Installation
Model 375MS/375AMS Flanged NRS x flanged NRS with
RV monitor switch
Model 375MSFSC/375AMSFSC With epoxy coated wye type
strainer (flanged only)
Model 375MSG/375AMSG With groove end gate valves
Model 375AMSBGVIC Supplied with groove x groove
body and grooved, tampered
Victaulic
®
butterfly valves
Model 375MSFG/375AMSFG With flanged inlet gate connection
and grooved outlet gate connection.
Model 375MSL/375AMSL Less shut-off valves
Model 375MSOSY/375AMSOSY With OS&Y gate valves
For Additional Information, reference WK-BPC catalog or visit
our web site.
To create a part number to fit your needs, see page 3 for an
example
Reduced Pressure Principle 375MS/375AMS
Pat. No. 5,425,393 and 5,913,331
Features Applications
2
1
/
2
”, 3”, 4”, 6”, 8”, 10”
Reduced pressure principle backflow prevention valve assembly with
integral relief valve monitor switch
Same features as the 375A
Completely sealed UL
®
recognized proximity switch factory installed –
Normally open contacts, weather resistant housing and wiring leads
ready for immediate installation to appropriate electrical circuit
In the event of a backflow condition, the relief valve closes an electrical
circuit, signaling that a possible relief valve discharge may be occurring
Approved by the Foundation for Cross Connection Control and
Hydraulic Research at the University of Southern California, ASSE
®
, CSA
®
(375AMSBGVIC 2
1
/
2
” – 8”)
UL
®
listed, C-UL
®
listed, FM
®
Approved
Building on the superior characteristics of the 375A / 375 reduced pressure principle series is the
375AMS and 375MS. Provided with a monitor switch in the relief valve, the MS series, when con-
nected to the proper electrical circuit, will provide confirmation that the relief valve is in a discharg-
ing condition. This is a highly useful configuration where the assembly may be installed in a remote
location, and the discharge could cause catastrophic water damage. The 375AMS and 375MS are
designed for high hazard application where preventing backpressure or backsiphonage is required.
Air gap (Model AG)
Thermal expansion tank (Model XT)
OS&Y gate valve supervisory switch (OSY-40)
Electronic solenoid timer (Model EST)
Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12” (305mm) and a maxi-
mum of 30” (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of
the unit can be submerged.
Quick test set (QT-SET)
Test cock lock (Model TCL24)
Solenoid control valve (ZW106)
Accessories
Model 375AMSBGVIC
imer
E
S
lectric
olenoid
T
12" MIN.
MODEL 375MSOSY
MODEL EST
MODEL ZW106
30" MAX.
375MS with ZW106 Solenoid Control Valve and EST
Electronic Solenoid Timer
DIRECTION OF FLOW
Backflow Preventers