Specifications
37
Tech Support: 855-ONE-ZURN
www.zurn.com
OptionsTypical InstallationX Ref
Model 975XLV FNPT x FNPT with swivel elbows
Model 975XLVS Supplied with bronze wye strainer
Model 975XLVFT Supplied with fast-test test cocks
For Additional Information, reference WK-BPC catalog or visit
our web site.
Reduced Pressure Principle with Swivel Elbows 975XLV Series
Features Applications
• 3/4”, 1”
• Reduced pressure principle backflow preventer consisting of a pressure
differential relief valve located between two independently operated
spring-loaded center guided check valves, wye pattern body
• Complete with two full port resilient seated ball valves for shut-off and
four resilient seated ball valve test cocks
• 90° swivel union elbow on inlet and outlet allows for easy conversion to
different configurations
• Compact design reduces space requirements for protective enclosures
• Eliminates the need for pipe elbows, nipples and unions
• Bronze body construction
• Replaceable Noryl
®
check seats
• Silicone check valve disc standard
• Entire unit serviceable in line
• Temperature range 33°F - 180°F
• Maximum pressure 175 psi
• Available with stainless steel handles (optional)
• ASSE
®
Listed 1013, IAPMO
®
Listed, AWWA Compliant (horizontal/
vertical), CSA
®
Certified (horizontal/vertical)
• Approved by the Foundation for Cross-Connection Control and
Hydraulic Research at the University of Southern California
Installation flexibility was the main focus when Wilkins created the 975XLV. In high hazard
applications, the 975XLV will protect against both backpressure and backsiphonage, while
allowing vertical up-up and up-down installation via the union connected elbows. The
sweeping elbows along with the superior design qualities of the 975XL, yield low head loss
and repeatability that Wilkins backflow preventers are known for.
Air gap (Model AG)
Thermal expansion tank (Model XT)
Soft seated check valve (Model 40XL)
Water hammer arrestor (Model 1250)
Local codes shall govern installation requirements. To be installed in accordance with the manufacturers’ instructions and the latest edition of the Uniform
Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12” (305mm) and a maximum of 30” (762mm) above
adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.
Quick test set (QT-SET)
Test cock lock (Model TCL24)
Ball valve monitor switch (Model BVMS)
Accessories
INDOOR VERTICAL INSTALLATION OUTDOOR HORIZONTAL INSTALLATION
12" MIN.
30" MAX.
12" MIN.
30" MAX.
AIR GAP
MODEL AG
MODEL 975XLV
MODEL 975XLV
FLOOR DRAIN
DIRECTION OF FLOW
DIRECTION OF FLOW
WILKINS WATTS CONBRACO
975LXV U009AQT 40-200-A2U (or Z)
975XLVS U009AQTS
Backflow Preventers