Specifications
26
Tech Support: 855-ONE-ZURN
www.zurn.com
Top Access Double Check Valve Assembly 950XLT Series
• 3/4”, 1”, 1
1
/
4
”, 1
1
/
2
”, 2”
• Top entry double check valve assembly consisting of two independently
operated, spring-loaded center guided check valves
• Complete with two full port resilient seated ball valves for shut-off and
four resilient seated ball valve test cocks
• Both check valves and test cocks are designed at an inclined angle up-
ward for easy access during repair, maintenance and testing
• Bronze body construction
• Test cocks are provided with threaded plugs
• Noryl
®
replaceable seats and silicone rubber check discs
• Entire unit serviceable in line
• Temperature range 33°F – 180°F
• Maximum pressure 175 psi
• With BSP threaded connections
• ASSE
®
Listed 1015, IAPMO
®
Listed, CSA
®
Certified.
• Approved by the Foundation for Cross-Connection Control and
Hydraulic Research at the University of Southern California
Model 950XLT FNPT x FNPT end connections
Model 950LXLT Less shut-off valves
Model 950XLTS Supplied with bronze wye strainer
Model 950XLTU Supplied with union connections between shut-off
valves and the device
Model 950XLTUS Same as 950XLTU except supplied with bronze
wye strainer
Model 950XLTFT Test cocks have Integral male 45° flare SAE test
fittings with threaded caps
Model 950XLTSH Supplied with stainless steel handles
For Additional Information, reference WK-BPC catalog or visit
our web site.
OptionsAccessoriesTypical InstallationX Ref Features Applications
When double check valve assemblies are installed in valve boxes, it is advantageous to have top
access to the check valves and test cocks. The Wilkins 950XLT embodies these advantages. Both
check valve access covers and test cocks are angled upward for easy access during testing and re-
pair. Designed for backflow protection where a health hazard does not exist, the 950XLT is perfect
for residential, commercial, and irrigation applications requiring a valve box installed double check.
Thermal expansion tank (Model XT)
Bronze wye strainer (Model S)
Stainless steel ball valve handles
Local codes shall govern installation requirements. To be installed in accordance with the manufacturer’s instructions and the latest edition of the Uni-
form Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12” (305mm) and a maximum of 30” (762mm)
above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be
submerged.
Quick test set (QT-SET)
Test cock lock (Model TCL24)
Ball valve monitor switch (Model BVMS)
3/4" – 1"
1
1
/
4
" – 2"
PIT INSTALLATION
PROTECTIVE
ENCLOSURE
DIRECTION OF FLOW
12" MIN.
MODEL 950XLTS
MODEL 950XLT
30" MAX.
DIRECTION OF FLOW
OUTDOOR INSTALLATION
WILKINS WATTS CONBRACO FEBCO AMES HERSEY
950XLT 007QT, 719QT 40-100-T2 850 200B, 2000B FDC
950LXLT 40-100-T1
Backflow Preventers