Installation Instructions
Table Of Contents
6 Synergize RF ILC Installation Instructions
Safety Warning
Safety Warning
Any work near high voltage can present a danger of electrical shock. Your
personal safety may be compromised if Aclara equipment is used in a manner
not specified by Aclara. All wiring must be installed in accordance with local
and national codes.
Required Tools
In addition to standard hand tools, the following special tools are required to
perform this procedure:
• 0-10 in-lbs. torque-limiting screwdriver
Installation Instructions
N
OTES
Only copper conductors should be used. Wire gauge is load dependent for
relays, and Aclara specifies a range of 30 to 10 AWG, with the maximum size
being 10 gauge for relay terminals. Minimum wire gauge should be determined
by the particular relay, the National Electric Code (NEC), and local standards.
AclaraONE version 1.4 or greater is required for full Intelligent Load Control
functionality.
The following procedure describes how to install an ILC device.
1. Using the appropriate hardware for the mounting surface, secure the ILC
device at the desired location by the three mounting tabs.