64 A c l a r a R F E l e c t r i c I - 2 1 0 + c U s e r G u i d e
Supported Alarms
comDevice.firmware.
decryption.failed
26.11.36.85 120 Firmware payload
failed decryption
comDevice.firmware.
signature.failed
26.11.103.85 120 DFW signature failed
digital signature
verification
electricMeter.Configuration.
Calibration.activated
3.7.18.4 120 Calibration mode
activated
ElectricMeter.RCDSwitch.
PrepaymentCredit.Expired
3.31.81.64 120 Open due to
prepayment
exhaustion
electricMeter.security.access
.uploaded
3.12.1.25 120 Meter reports it was
written
electricMeter.metrology.
readings.resetOccurred
3.21.87.215 113 Energy registers in
the meter have been
zeroed
comDevice.security.session.
failed
26.12.129.85 112 DTLS Handshake
failure
comDevice.firmware.status.
replaced
26.11.17.52 111 New DFW image has
been applied and is
running
comDevice.security.session.
succeeded
26.12.129.58 110 DTLS Handshake
success
electricMeter.loadControl.
EmergencySupplyCapacityLim
it. EventStopped
3.15.138.288 110 Emergency
Conservation Period
(ECP) has stopped
E2
electricMeter.metrology.Test
Mode.started
3.21.19.242 110 Meter reports test
mode initiated
E2
electricMeter.metrology.Test
Mode.stopped
3.21.19.243 110 Meter reports test
mode exited
E2
electricMeter.power.voltage.
frozen
3.26.38.88 110 DC bias detected E2
ElectricMeter.RCDSwitch.
Voltage.TamperDetected
3.31.38.257 110 synchronous load
side voltage present
electricMeter.power.voltage.
minLimitCleared
3.26.38.292 109 Q2
electricMeter.power.voltage.
minLimitReached
3.26.38.150 109 Low voltage Q2
electricMeter.power.voltage.
released
3.26.38.51 109 DC bias condition
cleared
E2
ElectricMeter.RCDSwitch.
SupplyCapacityLimit.
Disconnected
3.31.139.68 108 Open due to demand
limiting
E2
electricMeter.power.voltage.
lossDetected
3.26.38.47 107 Loss potential alarm
from revenue meter,
i.e., a voltage so low
that metrology
accuracy has been
compromised.
E2, Q2
electricMeter.loadControl.Su
pplyCapacityLimit.
EventStarted
3.15.139.287 105 Demand Limiting
Period (DLP) has
started
E2
Table 5.8
Aclara RF Network I-210+c Supported Alarms
IEC 61968-9 Description
IEC 61968-9
Appendix E
Code Priority Comment
Required
Switches