60 A c l a r a R F E l e c t r i c I - 2 1 0 + c U s e r G u i d e
Supported Quality Codes
Supported Quality Codes
The Aclara RF I-210+c solution may provide any of the quality codes found in
Table 5.6.
Table 5.6
Supported Quality Codes
Quality
Code Description Definition Severity
1.2.3 EndDevice.PowerQuality.
ServiceDisconnectSwitching
Service Disconnect operated during this
interval
1
1.2.32 EndDevice.PowerQuality. PowerFail Outage during interval 1
1.4.1 EndDevice.DataCollectionRelated.
OverflowConditionDetected
A numeric overflow condition for a
reading value or pulse counter was
detected in the meter.
3
1.4.2 EndDevice.DataCollectionRelated.
ParitalInterval
Partial (short) interval due to clock
change, power outage, or some similar
event.
2
1.4.3 EndDevice.DataCollectionRelated.
LongInterval
Long interval recorded due to a clock
change or some similar event.
2
1.4.4 EndDevice.DataCollectionRelated.
SkippedInterval
Skipped interval by the meter due to a
clock change or similar event.
3
1.4.5 EndDevice.DataCollectionRelated.
TestData
Data value was obtained while the
equipment was in test mode.
3
1.4.6 EndDevice.DataCollectionRelated.
ConfigurationChanged
The meter indicates that a configuration
change has occurred that may affect the
reading value or its interpretation.
3
1.4.9 EndDevice.DataCollectionRelated.
ClockChanged
The meter reports that one or more
changes to the clock time have occurred
in this interval. (The clock change was
metrologically significant for an interval
of this size or it would not be reported.)
2
2.4.63 MeteringSystem.DataCollectionRelated.
SignificantTimeBias
Time bias threshold exceeded during
this reading. This value was captured at
a time which differed from the target
time by a metrologically significant
amount.
2
2.5.257 MeteringSystem.unreasonable.
errorCode
The EP has replaced the useful data with
an error code. The <value> element, if
present, represents an error code and
not useful data.
Note: The EP may supply a value simply
because the protocol requires that a
non-zero byte count be supplied in the
message.
The meter also sometimes substitutes
values (such as 0x7fff) when it can't
supply a measurement because the
required hardware is missing.
In either of these cases, whenever a
placeholder code is supplied instead of
an actual reading, the
"knownMissingRead" error should also be
supplied.
3
2.5.259 MeteringSystem.unreasonable.
KnownMissingRead
Known missing read. (No amount of
retries will allow the HE to retrieve such
a reading.)
Note: The value could be missing due to
an internal error.
3
2.8.0 MeteringSystem.estimated. generic Supplied value is an estimate. 2