46 A c l a r a R F E l e c t r i c I - 2 1 0 + c U s e r G u i d e
Supported Measurements
0.8.15.6.20.1.8.0.0.0.0.0.0.0.0.3.63.0 maximum present indicating total
electricitySecondaryMetered demand
(kVAr)
K2, N2
0.8.15.6.4.1.8.0.0.0.0.0.0.0.0.3.63.0 maximum present indicating net
electricitySecondaryMetered demand
(kVAr)
K2, N2
0.8.15.6.20.1.8.0.0.0.0.0.0.0.0.3.61.0 maximum present indicating total
electricitySecondaryMetered demand
(kVA)
K2, N2
0.8.15.6.1.1.8.0.0.0.0.1.0.0.0.3.38.0 Maximum present indicating forward
electricitySecondaryMetered demand
touA (kW)
N2
0.8.15.6.19.1.8.0.0.0.0.1.0.0.0.3.38.0 maximum present indicating reverse
electricitySecondaryMetered demand
touA (kW)
N2
0.8.15.6.20.1.8.0.0.0.0.1.0.0.0.3.38.0 maximum present indicating total
electricitySecondaryMetered demand
touA (kW)
N2, T2
0.8.15.6.4.1.8.0.0.0.0.1.0.0.0.3.38.0 maximum present indicating net
electricitySecondaryMetered demand
touA (kW)
N2, K2
0.8.15.6.1.1.8.0.0.0.0.1.0.0.0.3.63.0 maximum present indicating forward
electricitySecondaryMetered demand
touA (kVAr)
K2, N2, T2
0.8.15.6.19.1.8.0.0.0.0.1.0.0.0.3.63.0 maximum present indicating reverse
electricitySecondaryMetered demand
touA (kVAr)
K2, N2, T2
0.8.15.6.20.1.8.0.0.0.0.1.0.0.0.3.63.0 maximum present indicating total
electricitySecondaryMetered demand
touA (kVAr)
K2, N2, T2
0.8.15.6.4.1.8.0.0.0.0.1.0.0.0.3.63.0 maximum present indicating net
electricitySecondaryMetered demand
touA (kVAr)
K2, N2, T2
0.8.15.6.20.1.8.0.0.0.0.1.0.0.0.3.61.0 maximum present indicating total
electricitySecondaryMetered demand
touA (kVA)
K2, N2, T2
0.8.15.6.1.1.8.0.0.0.0.2.0.0.0.3.38.0 Maximum present indicating forward
electricitySecondaryMetered demand
touB (kW)
N2, T2
0.8.15.6.19.1.8.0.0.0.0.1.0.0.0.3.38.0 maximum present indicating reverse
electricitySecondaryMetered demand
touB (kW)
N2, T2
0.8.15.6.20.1.8.0.0.0.0.2.0.0.0.3.38.0 maximum present indicating total
electricitySecondaryMetered demand
touB (kW)
N2, T2
0.8.15.6.4.1.8.0.0.0.0.2.0.0.0.3.38.0 maximum present indicating net
electricitySecondaryMetered demand
touB (kW)
N2, T2
0.8.15.6.1.1.8.0.0.0.0.2.0.0.0.3.63.0 maximum present indicating forward
electricitySecondaryMetered demand
touB (kVAr)
K2, N2, T2
Table 5.5
Measurement Supported by NIC Firmware Version 1.70 within Daily Shifted and On-Request Messages
IEC 61968-9 Appendix C Code IEC 61968-9 Description
Required
Softswitches