Final Assembly of SCG DCU
Document No.: AP-1X700-003-MAD Rev. D Page 5 of 12
Proprietary Document and Information of Aclara
Uncontrolled when printed unless marked ‘Controlled’ or ‘Production Copy’ with a date in red
4.2 Assemble and install the DCU cover.
4.2.1 Install the strike plate (056-9975X-2) as shown in Figure 3.
Using a clean cloth and Isopropyl Alcohol, clean the surface where the strike plate is to be
installed.
Orient fixture FIX-1X700-002 as shown, holding the corner of the fixture firmly into the inside
corner of the enclosure cover.
Remove the paper backing of the strike plate and place using the inside corner of the fixture as a
guide.
Remove the fixture press the strike place firmly to insure complete adhesion to the stainless steel
cover.
Figure 3: Install Strike Plate
056-9975X-2
Inside of Enclosure Cover
056-10700-2
Strike Plate
Fixture
FIX-1X700-002