74 D C U M a i n t e n a n c e a n d O p e r a t i o n M a n u a l
Cell Module CCID1=8914800000
Each call
attempt
X X
First 10 characters of Circuit Card Interface Devices
(CCID). Message value indicates the cell network that
the CDMA cell phone is connected to at the time of the
call.
Cell Module CCID2=2805604979
Each call
attempt
X X
Last 11 characters of Circuit Card Interface Devices
(CCID). Message value indicates the cell network that
the CDMA cell phone is connected to at the time of the
call.
Cell Module CCSQ=28
Each call
attempt
X X
Message value indicates cell phone signal strength. This
number ranges from 0 (weakest) to 31 (strongest) or 99
(no service).
Cell Module CESN=FFFFFFFF
Each call
attempt
X
Electronic serial number (ESN) of the cell module for a
CDMA phone.
Cell Module CHWV=0.00
Each call
attempt
X X Message value indicates hardware version of cell phone.
Cell Module CNET1=Verizon
Each call
attempt
X X Cell phone carrier name.
Cell Module CNET2=
Each call
attempt
X X
Remaining characters if cell phone carrier name is
greater than 11 characters.
Cell Module CNET3=
Each call
attempt
X X
Remaining characters if cell phone carrier name is
greater than 22 characters.
Cell Module CnktErr 1
Logged after
failed call
attempt
X X
Ethernet UART Error: The UART IC (U119) failed, the
cable to the modem is disconnected, or the modem is
locked up.
Cell Module CnktErr 2
Logged after
failed call
attempt
X X
Modem Error - Could not communicate with the modem
or could not connect to the Headend. Usually an
indicator of a Headend IP network issue. May also
occur when Headend is not ready to receive data or all
phone lines are busy.
Cell Module CnktErr 3
Logged after
failed call
attempt
X X
Data Transfer Error - Modem connected to the NCC, but
there was a problem transferring the data. This could be
due to network latencies due to excessive traffic or
multiple CRC communications errors.
Cell Module CnktErr 4
Logged after
failed call
attempt
X X
Command Error - Haven’t received an NCC Command
within the established Timeout period (usually 5
minutes).
Cell Module CnktErr 5
Logged after
failed call
attempt
X X
Socket Error (Connection Lost) - Connection to TCP/IP
DCU Server has been lost.
Cell Module CnktErr 6
Logged after
failed call
attempt
X X
Socket Error (Cannot Create Socket) - Cannot create a
socket. Usually, an invalid or nonexistent IP address or
some other internal RTOS error.
Source Message Frequency DCU 2 DCU 2+
Mainboard
Firmware
Description