66 D C U M a i n t e n a n c e a n d O p e r a t i o n M a n u a l
Non-absorb charge state report
interval = 6(minutes)
Frequency of firmware reporting of power statistics when battery is Float Mode (steady
voltage)
Expected Values: 0=Inactive, 1 to 144 (10 to 1440 minutes) Default Value = 6 (60
minutes).
No charge state report interval =
0(minutes)
Frequency of firmware reporting of power statistics when battery is discharging
Expected Values: 0=Inactive, 1 to 144 (10 to 1440 minutes) Default Value = 6 (60
minutes).
Absorb charge state readings =
0x7E
Identifies the battery parameters to return in absorb and bulk modes based on bit mask:
0x01 = Power Supply Temperature
0x02 = State of Charge
0x04 = Input Current
0x08 = Input Voltage
0x10 = Battery Temperature
0x20 = Charge Current
0x40 = Battery Voltage
0x80 = System Voltage
Default value = 0x7E (which brings back everything except System Voltage and Power
Supply Temperature
Non-absorb charge state
readings = 0x7E
Identifies the battery parameters to return in float modes based on bit mask:
0x01 = Power Supply Temperature
0x02 = State of Charge
0x04 = Input Current
0x08 = Input Voltage
0x10 = Battery Temperature
0x20 = Charge Current
0x40 = Battery Voltage
0x80 = System Voltage
Default value = 0x7E (which brings back everything except System Voltage and Power
Supply Temperature)
No charge state readings = 0x7E
Identifies the battery parameters to return in discharge modes based on bit mask:
0x01 = Power Supply Temperature
0x02 = State of Charge
0x04 = Input Current
0x08 = Input Voltage
0x10 = Battery Temperature
0x20 = Charge Current
0x40 = Battery Voltage
0x80 = System Voltage
Default value = 0x7E (which brings back everything except System Voltage and Power
Supply Temperature)
Field Example Description