Product Info

DRAFT 8-1-2019 Technical Brief
A c l a r a R a d i o M o d u l e I m p l e m e n t a t i o n R e q u i r e m e n t s 8
RF Exposure
RF Exposure
Exposition aux RF
Host products using the ARM could perform
many different functions requiring different
operational parameters. The host product
will meet the FCC and ISED RF exposure
limitations for uncontrolled areas at a
distance >20 cm. This can be obtained with
the adjustment of power output, transmission
duty cycle, or both. For products that are to
be installed within a controlled area, the
exposure limits may be relaxed to the levels
required for controlled areas with the
addition of any warnings that might be
required for this situation.
Les produits hôtes qui utilisent le module
ARM pourraient effectuer différentes
fonctions qui requièrent des paramètres
d’exploitation variés. Le produit hôte
respectera les limites d’exposition aux RF de
la FCC et de l’ISED pour les zones non
contrôlées à une distance >20 cm. Cela peut
être obtenu en ajustant la puissance de sortie,
le cycle d’utilisation de la transmission, ou les
deux. Pour les produits pour installation dans
une zone contrôlée, les limites d’exposition
peuvent être allégées aux niveaux requis pour
les zones contrôlées avec l’ajout des
avertissements requis par la situation.
Using the power levels given above with the
max gain antenna, the following conditions
will meet the RF exposure limitation for
uncontrolled areas at a distance of 20 cm.
En utilisant les puissances données ci
-
dessus
pour le gain d’antenne maximal, les conditions
suivantes respectent les limites d’exposition
aux RF pour les zones non contrôlées à une
distance de 20 cm.
Rang
e
EIRP
Duty Cycle
Standard
853 mW EIRP
100%
Extended
2606 mW EIRP
32%
Maximum
3396 mW EIRP
25%
Portée
PIRE
Cycle de service
Standard
853 mW
PIRE
100
%
Étendue
2606 mW
PIRE
32
%
Maximum
3396 mW
PIRE
25
%