Elster / AMCO Gas Meter MTU Installation Instructions
3. Remove and retain the gasket..
NOTE: In addition to the gasket shown, some index covers use a silicone gasket. In this case, ensure
that the silicone gasket remains attached to the index cover and is not damaged.
4. Remove the four screws securing the baseplate to the meter. Discard the base plate.
NOTE: If more than two screws are broken, or if two screws are broken and they are not on opposite
diagonal sides, the MTU should not
be installed.