Installation Instruction
3
MTU Single Port Pulse Devices Installation Instructions
Use and Setup Instructions:
Recommended Tools
• Safety glasses
• Torque Limiting Screw Driver
• 3/8" Cordless drill
• 1/4" Drill bit
• 9/16" Stapler and staples
• Wire cutters
• Needle-nose pliers
• Wire stripper
• Connector crimping tool 3M™ E-9Y
• Screwdrivers, assorted Phillips and slotted
• MTU Programmer with cable, programming coil and STAR Programming Software
• Mounting screws
N
OTE
The mounting kit contains the exact quantity of hardware required for a single installation. Keep
extra hardware on hand.
N
OTE
No repair or maintenance of MTU is required. Defective MTU will be replaced.
N
OTE
MTU may be wiped with damp cloth to prevent electrostatic charge hazard.
Scope
The Single Port Pulse MTU is for use with:
• gas meters that are outfitted with a third party pulse module;
• pulse units without a tamper detection circuit
Mount the MTU
MTUs must be positioned and mounted properly to ensure optimum RF signal propagation. Each MTU
contains an internal antenna near the top front surface of the sealed enclosure. As a result, the MTU
should always be mounted vertically and the Aclara logo should face the installer.