22 TWACS
®
-ORION
®
for UMT Products User Guide
EMTR3 Menu
EMTR3 Menu
The Electric Meter Transceiver 3 (EMTR-3) contains the equivalent of network
routing tables that must be maintained. The EMTR-3 maintains a routing table that
is built upon its port list, which reserves a given port for a given Intelligent End
Device (IED). The HHTR-3 can be used to manually create, modify, or remove
these port list assignments.
There are two options for inserting an IED into the EMTR-3’s port list: Listen
Mode and direct access to the Port List. Both options provide the same installation
with different aspects of the process being automated. Whether automated or
manual, the process gathers the IED serial number, service type, and desired port
location for installation.
The user must know the serial number of the EMTR-3 and manually enter it into
the HHTR-3 to establish a communication link with the EMTR-3.
N
OTES
When entering an ORION gas or water IED serial number for installation, if the
serial number is less than 79,999,999, drop the first digit, “7”, and enter the
seven remaining digits. For all ORION gas and water IEDS with serial numbers
equal to or greater than 80,000,000, enter all digits of the IED, which will be
from 8 to 10 digits.
There is no direct communication between the Intelligent End Device (IED) and
the HHTR-3.
Use the following procedures to navigate the EMTR3 menu screens.
1. On the Main Menu use the navigational keys to place the cursor to the left
of EMTR-3.
2. Press the Enter key to view the EMTR3 menu.
Main Menu
TWACS
HHTR Config
Serial Com
PC UploadEMTR-3
EMTR3 Menu
RCE Change Out
EMTR-3 Status
Manage IEDs