Chapter 2 • Testing, Troubleshooting, and Maintenance
Reading: displays the number on the ORION. A correct number
(0000000000-9999999999) here verifies proper equipment
operation.
12. Press the down arrow or the Enter button.
Ignore Meter Com.
Ignore the Hist MTR Com entry for installation purposes.
LeakDet options are Y or N (Water only). If Y, a site visit is
required to locate the leak. Clear error and reset the meter onsite after
correcting the leak.
Leak detect trips at the meter if total consumption is continuously
incremented. After no continuous consumption for a period of time
(determined by the meter manufacturer) the meter will automatically
reset.
Tamper options are Y or N. Clear error and reset the meter onsite
after correcting tamper source.
13. Press the down arrow or the Enter button.
RSSI (Received Signal Strength Indicator) displays the received
signal strength. The range is 0-255 with 255 being the highest
strength.
14. Press the down arrow or the Enter button
Ignore this screen for installation purposes.
Orion Com Status
Battery: N/A
Reading: 1234567890
N/V Memory: N/A
Orion Com Status
Hist MTR Com: N/A
Meter Com: N/A
LeakDet: N Tamper: N
Orion Com Status
RF Link Data:
PA: N/A
Link: N/A
RSSI: 123
Last Ch: N/A
RF Link Data:
Acq Failures: 0
Orion Com Status