User's Manual
Table Of Contents
26 TWACS
®
- ORION
®
for CENTRON
®
Meter User Guide
Troubleshooting Scenarios
HHTR Displayed Error Codes
The following table lists the error code number and error message text that
the HHTR displays when the specific error is encountered while using the
HHTR to communicate with the TWACS-ORION system.
Table 0.1
Error Code Description and Solution
Error Description Solution
The following error codes are RF communication errors.
01 RF Error General error. Retry the command.
02 Service Not Supported Service is not supported. Retry the command.
03 Not used
04 Operation Not Possible RF error. Retry the command.
05 Inappropriate Action
Requested
RF error. Retry the command.
06 RF Device Busy RF error. Retry the command.
07 Data From Device Not
Ready
RF error. (Usually memory) Retry the command.
31 RF Device Sent NAK RF error Retry the command.
32 Can not acquire an RF Link RF error Retry the command.
33 Operation Timed Out Operation time expired without
success.
Retry the command.
The following error codes are internal HHTR or user errors.
101 RF PIC sends a NAK The RFPIC isn't ready or doesn't
understand the command. The RF
PIC internal to the HHTR has
failed.
Retry the command.
102 RF PIC is busy RFPIC is performing another
operation and is currently busy.
The RF PIC internal to the HHTR
was in the middle of another
command.
Retry the command.
103 No response from RF PIC
on HHTR
The RFPIC isn't responding to the
UI. No Response from the RF
PIC. The RF PIC didn't respond
to the UI processor.
Retry the command.
104 RF PIC send invalid
response
The RFPIC sent an invalid
response to the UI. The HHTR UI
processor didn't recognize the
response from the RF PIC.
Retry the command.
105 Operation canceled Indicates the Esc button was
pressed during an operation.
The user aborted the last
command.
106 RMTR-EMTR session
failed
The HHTR timed out waiting for
the RMTR to respond back to the
HHTR.The HHTR was unable to
link to the requested EMTR.
Verify the serial number