User`s guide
System Board 1-27
Table 1-6 System Error Messages (continued)
Error Message Corrective Action
Floppy Disk Controller
Error
Check the floppy drive cable and its
connections. If the cable is good and
properly connected, the floppy disk
controller may be the problem. Change
the floppy disk controller or disable the
onboard controller by installing another
add-on card with a controller.
CPU Clock Mismatch When the user changes the CPU
frequency, this message will be shown
once. Then the BIOS will adjust the
CPU clock automatically.
Serial Port 1 Conflict
Serial Port 2 Conflict
Change the onboard serial port address
in Setup or change the add-on card
serial port address.
Parallel Port Conflict Change the onboard parallel port
address in CMOS Setup or the parallel
port address of the add-on card.
Real Time Clock Error Check the RTC circuit or replace the
RTC.
CMOS Battery Bad Replace the onboard lithium battery.
CMOS Checksum Error Run Setup again and reconfigure the
system.
NVRAM checksum Error Run the ECU (Extended ISA
Configuration Utility) to restore the
original EISA configuration data.
On Board xxx ...
Conflict(s)
Try to reassign or disable onboard
device resources.
PCI Device Error Check the PCI card. Replace it if bad.
System Resource
Conflict
Run Setup to reconfigure the system.
IRQ Setting Error Run Setup to reconfigure the system.
Expansion ROM
Allocation Fail
Change the I/O expansion ROM
address.