User Manual
Table Of Contents
- Predator Triton 515-51 Service Guide V1.00
- CHAPTER 1 - Hardware Specifications
- CHAPTER 2 - System Utilities
- CHAPTER 3 - Machine Maintenance
- Machine Maintenance
- Machine Disassembly and Replacement
- Disassembly Process
- Main Unit Disassembly Process
- Main Unit Disassembly Flowchart
- Removing the Lower Case
- Removing the Battery Pack
- Removing the WLAN Module
- Removing the RTC Battery
- Removing the DC-In Cable
- Removing the Mainboard
- Removing the Touchpad Module
- Removing the Left and Right Speakers
- Removing the WLAN Antenna
- Removing the Turbo Key Module
- Removing the Memory Modules
- Removing the SSD Modules
- Removing the Thermal Module
- Removing the Upper Case
- LCD Module Disassembly Process
- LCD Module Reassembly Process
- Main Unit Reassembly Process
- Replacing the Upper Case
- Replacing the Thermal Module
- Replacing the SSD Modules
- Replacing the Memory Module
- Replacing the Turbo Key Module
- Replacing the WLAN Antenna
- Replacing the Left and Right Speakers
- Replacing the Touchpad Module
- Replacing the Mainboard
- Replacing the DC-In Cable
- Replacing the RTC Battery
- Replacing the WLAN Module
- Replacing the Battery Pack
- Replacing the Lower Case
- Machine Maintenance
- CHAPTER 4 - Troubleshooting
- CHAPTER 5 - Jumper and Connector Locations
- CHAPTER 6 - FRU List
- CHAPTER 7 - Test Compatible Components
- CHAPTER 8 - Online Support Information
Troubleshooting 4-19
Intermittent Problems 0
Intermittent system hang problems can be caused by a variety of reasons that have nothing to
do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software
errors. FRU replacement should be considered only when a recurring problem exists.
When analyzing an intermittent problem, perform the following:
1. Run the advanced diagnostic test for the system board in loop mode at least 10 times.
2. If no error is detected, do not replace any FRU.
3. If an error is detected, replace the FRU. Rerun the test to verify that there are no more
errors.
Undetermined Problems 0
The diagnostic problems does not identify which adapter or device failed, which installed
devices are incorrect, whether a short circuit is suspected, or whether the system is
inoperative.
Perform the following procedures to isolate the failing FRU (do not replace non-defective
FRU).
NOTE:
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly.
1. Remove power from the computer.
2. Visually check the components for damage. If any problems are found, replace the FRU.
3. Remove or disconnect all of the following devices:
Non-Acer devices
Printer, mouse, and other external devices
Battery pack
Hard disk drive
DIMM
CD-ROM/Diskette drive Module
PC Cards
4. Apply power to the computer.
5. Determine if the problem has changed.
6. If the problem does not recur, connect the removed devices one at a time until failing FRU
is found.
7. If the problem remains, replace the following FRUs one at a time. Do not replace a
non-defective FRU:
Mainboard
LCD assembly