Technical data

66 Chapter 4 Subsystem Architecture and Components
4.6.1 AMS200 Rack-Mount Model
Each RKS unit contains the physical disk drives, including the disk array groups and the
dynamic spare disk drives. Each rack frame has dual power plugs, which should be attached
to two different power sources or power panels.
The AMS200 can be configured with 1 RK and up to 6 RKAJ units for a total of 105 GB disk
drives at a maximum of 28.1 Tbytes RAID5(14D+1P) (using the 287.6 G disk drive). The
AMS200 can also be configured with 1 RKS and up to 6 RKAJAT units for a total of 105 disk
drives at a maximum of 37.0 Tbytes RAID5(14D+1P) (using the 393.9 G disk drive).
Table 4.3 Basic Specifications of Rack-Mount Model
Item
Model
Rackmount model
RKS RKAJ RKAJAT RKNAS
Configuration Configuration 1 RKS 1RKAJ 1RKAJAT 1RKNAS
System appearance
Disk drive
used
Disk drive size
(W×D×H) (mm)
101.6×146.1×25.4
Data capacity (G byte)
(Note 1)
71.3/143.3/287.6 245.7/393.4
Rotational speed (min
-1
)
For 71.3/143.3 G bytes: 10,000/15,000
(Note 3)
For 287.6 G bytes: 10,000
7,200
Maximum mountable
quantity(unit)
15
Host interface Interface type 2 G bps Fibre Channel
Optical (Non-OFC)
(Note 3)
1 Gbps iSCSI
(Ethernet)
(Note 5)
1Gbps Ethernet
Data transfer speed
(i.e. maximum speed for
transfer to host)
200 M bytes/s
(Fibre Channel)
(Note 4)
100 M bytes/s (iSCSI)
(Note 5)
100 Mbytes/s
(Ethernet)
Single
controller
Fibre Channel: 1 (Note
2)
iSCSI: 2 (Note5)
(
Number of
host
connectors
Dual
controller
Fibre Channel: 2 (Note
2)
iSCSI: 4 (Note5)
( 8
(4 for 1RKNAS)
Transferred block size
(bytes)
512