Datasheet
Datasheet, Volume 1 77
Electrical Specifications
3. The loadlines specify voltage limits at the die measured at the VCC_SENSE and VSS_SENSE lands. Voltage
regulation feedback for voltage regulator circuits must also be taken from processor VCC_SENSE and
VSS_SENSE lands. Refer to the Voltage Regulator Down (VRD) 11.1 Design Guidelines for socket load line
guidelines and VR implementation.
Figure 7-1. V
CC
Static and Transient Tolerance Loadlines
VID - 0.000
VID - 0.013
VID - 0.025
VID - 0.038
VID - 0.050
VID - 0.063
VID - 0.075
VID - 0.088
VID - 0.100
VID - 0.113
VID - 0.125
VID - 0.138
VID - 0.150
VID - 0.163
VID - 0.175
VID - 0.188
0 102030405060708090100110
Icc [A]
Vcc [V]
Vcc Typical
Vcc Minimum
Vcc Maximum