Appendix A: Embedded SATA RAID Technology for the Altos G310 Mk2
114
Note that the logical drive should be at a RAID 1 level to start
check consistency. If you select a RAID 0 logical drive, a message
displays stating that a check consistency cannot be performed.
To de-select a logical drive, press the space bar again.
3 Press <F10>.
4 At the prompt, select Yes to start check consistency and press
<Enter>.
If you press <Esc> while the check consistency is in progress, the
following options display:
• Stop: The CU stores the percentage of the check consistency
already completed. When you restart the check consistency, it
continues from the last percentage completed rather than
from zero percent.
• Continue: Check consistency continues normally.
• Abort: The check consistency is completely aborted. If you
restart check consistency, it begins at zero percent.