Service manual

7. Assembly and Disassembly Procedures (continued)
Part Numbe r Part Nam e
7115240121P0A SCREW _M4*12_DOUBLE WASHIER 4 Screw Size=M4x12; Torque=12~14KGF.CM
7740412200P0A STAND_BASE_ACER_AL1717_#6800_ABS 94HB 1 -
-- --
-- --
-- --
7737517400P0A FC ASSY_#6790/#6810_ABS94V0_ACER_T17BNHW 1 -
5113800899P T17BNHW-G1(99)_ACER_FUN CTION KEY BD 1 -
7140130061P0A SCREW _MACH INE_WITHOUT_NINDING_M3_6L_BLA 2 Screw Size=M3x6; Torque=6~8KGF.CM
Spare Parts Usage
Q'ty Remark
S6
Turn over the LCD monitor (screen faced up).
S7
Place cloth on the panel where you are working on to protect
the panel. Continuely, wedge your finger between the front
bezel and the panel, then pry up on the front bezel to
disengage the locking mechanism.
S8
W ork your way along the front bezel to disengage all the
locking mechanism.
S9
Once all the locking mechanism s are release from front bezel;
remove the bezel carefully.
U s e a P hillip s - head screwdriver unscrewed number 1~2 screws
to release the Key Function board from the Front Bezel.
S10
S5
U s e a P hillip s - head screwdriver unscrew 4 screws to release
the stand base.
Steps Photo
Procedures
2
1
Key Function cable
Go to cover page
47
ACER AL1716W