194 Spheras Storage Director Installation and User Guide
5 Navigate to and select the image file name.
6Click Open. The .ima file name is displayed in the “New firmware image file on” field. The details of the firmware
file are displayed in the “New firmware image information” field.
Figure 106 Upgrade Firmware Details
7Click OK.
8 A warning message, “This firmware update requires the controller to reboot. The reboot takes approximately 30
seconds to complete. Any I/O must be stopped.” is displayed.
9Click Ye s to complete the firmware update. Click No to cancel the firmware update.
7.9 Reconditioning a Battery Backup Unit
The status of the battery pack is continuously monitored by the gas gauge. The gas gauge does not read the actual
charge on a battery pack, but measures and tracks the current into and out of the battery pack. The gas gauge is
synchronized to the battery pack condition by performing a full discharge cycle followed by a charge cycle. A new
battery pack must first be discharged and fully charged followed by another discharge and charge cycle. This process
continues until the remaining capacity value is close to the full charge capacity value. A recondition cycle is performed
the first time a battery pack is connected and repeated periodically. The frequency of recondition cycles is determined
by the number of discharges. Any time a battery pack is disconnected and reconnected, a recondition cycle is
performed. Additionally, when a controller or the module containing the battery pack is removed, a recondition cycle is
performed.
Follow these steps to perform a Battery Recondition: