184 Spheras Storage Director Installation and User Guide
897 Name MLXEV_FATAL_BRKP
Description Internal controller firmware breakpoint.
Cause Internal controller has encountered a firmware breakpoint.
Action Power controller off and on.
Address ctl: 0 version: 13.14 – 15 param: 0x23222120
Severity 1 (Serious)
Source InPro
Paramtype value
912 Name MLXEV_I960_HW_ERROR
Description Internal controller i960 processor error.
Cause Internal controller has encountered i960 processor specific error.
Action Power controller off and on.
Address ctl: 0 version: 13.14 – 15 param: 0x23222120
Severity 1 (Serious)
Source InPro
Paramtype value
Params 0x80008001 : name_HW_PATU_ERROR :
“Error in Primary Address translation unit”
0x80008002 : name_HW_SATU_ERROR :
“Error in Secondary Address Translation unit”
0x80008003 : name_HW_PBI_ERROR :
“Error in Primary side of PCI to PCI Bridge Unit”
0x80008004 : name_HW_SBI_ERROR :
“Error in Secondary side of PCI to PCI Bridge Unit”
0x80008005 : name_HW_ABI_ERROR :
“Error in Bus Interface Unit”
0x80008006 : name_HW_DMA0_ERROR :
“Error in DMA Unit , Ch0”
0x80008007 : name_HW_DMA1_ERROR :
“Error in DMA Unit , Ch1”
0x80008008 : name_HW_DMA2_ERROR :
“Error in DMA Unit, Ch2”
0x80008009 : name_HW_IntNMI_ERROR :
“Error caused by Software interrupt”
0x8000800A : name_HW_ExtNMI_ERROR :
“Error caused by External Source”
928 Name MLXEV_SARM_HW_ERR
Description Internal controller Strong-ARM processor error.
Cause Internal controller has encountered Strong-ARM processor specific
error.
Action Power controller off and on.
Address ctl: 0 version: 13.14 – 15 param: 0x23222120
Severity 1 (Serious)
Source InPro
Paramtype value
944 Name MLXEV_SCSI_HW_ERR
Description Internal controller back end hardware error.
Cause Timeout waiting for interrupt.
Timeout waiting for command completion.
Action Power controller off and on.
Address ctl: 0 version: 13.14 – 15
Severity 1 (Serious)
Source InPro
Total events = 276
Table 2 RAID Controller Event Codes