176 Spheras Storage Director Installation and User Guide
702 Name MLXEV_LOG_REQUEST_SENSE
Description Request sense.
Cause A physical disk has generated an error.
Action Interpret the Key/ASC/ASCQ and take appropriate action.
Address ctl: 0 chn: 13 tgt: 14
Severity 4 (Information)
Source ExPro
703 Name MLXEV_LOG_SET_RTC
Description Set real time clock.
Cause Real time clock was set.
Action None
Address ctl: 0 chn: 13
Severity 4 (Information)
Source ExPro
800 Name MLXEV_CFG_NEW
Description New configuration received.
Cause A new configuration was downloaded to controller.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
801 Name MLXEV_CFG_CLEAR
Description Configuration cleared.
Cause Controller was told to clear the configuration.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
802 Name MLXEV_CFG_INVALID
Description Configuration invalid.
Cause The controller found an invalid configuration.
Action None
Address ctl: 0
Severity 3 (Warning)
Source ExP_old
803 Name MLXEV_CFG_COD_ACCESS_ERROR
Description Configuration on disk access error.
Cause The controller could not read the configuration off the disk.
Action None
Address ctl: 0
Severity 3 (Warning)
Source ExP_old
804 Name MLXEV_CFG_COD_CONVERTED
Description Configuration on disk converted.
Cause The controller converted a down level configuration on disk.
Action None
Address ctl: 0
Severity 3 (Warning)
Source ExP_old
Table 2 RAID Controller Event Codes