User Guide

174 Spheras Storage Director Installation and User Guide
517 Name MLXEV_SYSTEM_DEAD
Description Lost connection to the server or server is down.
Cause Lost network connection to the server.
Server shutdown.
Action None
Address None
Severity 1 (Serious)
Source Client
518 Name MLXEV_AUTOBOOT_CHANGED
Description Automatic reboot count has changed.
Cause Controller has rebooted.
Automatic reboot has rearmed itself or was reconfigured.
Action None
Address ctl: 0 param: 0x2120
Severity 4 (Information)
Source ExPro
Paramtype value
519 Name MLXEV_BBU_BATT_TEST_START
Description Battery test has started.
Cause Battery test has started.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
520 Name MLXEV_BBU_BATT_TEST_COMPLETE
Description Battery test has completed.
Cause Battery test has completed.
Action See battery test status for completion mode.
Address ctl: 0
Severity 4 (Information)
Source ExPro
521 Name MLXEV_BBU_BATT_TEST_CANCELED
Description Battery test cancelled.
Cause Battery test cancelled.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
522 Name MLXEV_BBU_BATT_TEST_FAILED
Description Battery test failed, battery bad.
Cause Battery test failed, battery bad.
Action Replace battery.
Address ctl: 0
Severity 2 (Error)
Source ExPro
640 Name MLXEV_CHANNEL_FAILED
Description Channel failed.
Cause Cable disconnected.
Action Plug in cable.
Address ctl: 0 chn: 13
Severity 3 (Warning)
Source Unspecified
Table 2 RAID Controller Event Codes