User Guide
© 2003, Adaptec, Inc. 173
440 Name MLXEV_CTLDEV_MIRROR_RACE_TABLE_ERROR
Description Error in mirror race table.
Cause Logical drives appear in the mirror race table that do not exist in the
configuration.
Possible data integrity issue.
Action Check configuration for accuracy, run consistency check and restore
consistency.
Address ctl: 0 logdrv: 15
Severity 1 (Serious)
Source ExPro
441 Name MLXEV_CTLDEV_STOP_REJECTED
Description A replacement controller attempted to stop the surviving controller.
Cause Incompatible replacement controller firmware or hardware.
Action Obtain a compatible replacement controller.
Address ctl: 0
Severity 2 (Error)
Source ExPro
512 Name MLXEV_SYSTEM_STARTED_NEW
Description System started.
Cause The server system (or array management utility server) started.
Action If you did not expect a system reboot, investigate.
Address –
Severity 4 (Information)
Source InPro
513 Name MLXEV_SYSTEM_SIZE_TABLE_FULL
Description Size table full.
Cause Too much physical device size information is defined.
Action Remove unused device information from this system.
Address None
Severity 4 (Information)
Source InPro
514 Name MLXEV_SYSTEM_USER_LOGGED_IN
Description User logged in.
Cause An array management utility user logged in on the server system.
Action Not available.
Address None
Severity 4 (Information)
Source InPro
515 Name MLXEV_SYSTEM_USER_LOGGED_OUT
Description User logged out.
Cause An array management utility user logged out of the server system.
Action Not available.
Address None
Severity 4 (Information)
Source InPro
516 Name MLXEV_SYSTEM_ALIVE
Description Server alive.
Cause Reconnected to server.
Server rebooted.
Action None
Address None
Severity 4 (Information)
Source InPro
Table 2 RAID Controller Event Codes