Name MLXEV_CTLDEV_MIRROR_RACE_RECOVERY_FAILED
Description Mirror race recovery failed.
Cause Some physical disks may have failed.
Action Run consistency check and restore consistency.
Address ctl: 0
Severity 1 (Serious)
Source InPro
428 Name MLXEV_CTLDEV_MIRROR_CRITICAL_DRIVE
Description Mirror race on critical logical drive.
Cause Logical device is critical.
Action Replace failed physical disk and rebuild.
Address ctl: 0
Severity 1 (Serious)
Source InPro
429 Name MLXEV_CTLDEV_IN_CLUSTER
Description Controller connected to cluster.
Cause One or more controllers detected during scan and entered nexus with
those controllers.
Action None
Address None
Severity 4 (Information)
Source InPro
430 Name MLXEV_CTLDEV_NOT_IN_CLUSTER
Description Controller disconnected from cluster.
Cause All other controllers in cluster are inaccessible due to controller
powered off, controller failure, or cable failure.
Action If this was an unexpected event, refer to service manual and correct the
failure.
Address None
Severity 4 (Information)
Source InPro
431 Name MLXEV_SYSDEV_DATA_LOSS_IMPROPER_SHUTDOWN
Description Controller improperly shutdown. Data might have been lost.
Cause User improperly shutdown the controller, resulting in inconsistent
logical drive and/or lost data.
Action Run consistency check to verify logical drive consistency.
If needed, restore data from backup.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source InPro
432 Name MLXEV_CTLDEV_AUTOMATIC_FLASH_STARTED
Description Dual-active automatic flash of replacement controller.
Cause Replacement controller is being flashed with survivor’s firmware.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
433 Name MLXEV_CTLDEV_NEGOTIATION_FAILED_JUMPERS
Description Dual-active negotiation failed jumpers.
Cause Jumper settings do not match.
Action Replace, adjust, or add components so that the controllers have the
same jumper settings.
Address ctl: 0
Severity 2 (Error)
Source ExPro