412 Name MLXEV_CTLDEV_NORMAL_CACHE_MODE
Description Controller entered normal cache mode.
Cause –
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
413 Name MLXEV_CTLDEV_DEV_START_CMPLT
Description Controller device start complete.
Cause
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
414 Name MLXEV_CTLDEV_SOFT_ECC_CORRECTED
Description Soft ECC error corrected.
Cause Faulty memory module.
Action Replace memory module
Address ctl: 0
Severity 2 (Error)
Source ExPro InPro
415 Name MLXEV_CTLDEV_HARD_ECC_CORRECTED
Description Hard ECC error corrected.
Cause Faulty memory module.
Action Replace memory module.
Address ctl: 0 chn: 13 tgt: 14
Severity 2 (Error)
Source ExP_old InPro
416 Name MLXEV_CTLDEV_BBU_RECOND_NEEDED
Description Battery recondition suggested.
Cause –
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
417 Name MLXEV_CTLDEV_REMOVED_PTNR
Description Controller's partner has been removed.
Cause Controller was removed or controller was ordered shutdown.
Action None
Address ctl: 0
Severity 3 (Warning)
Source ExP_old
418 Name MLXEV_CTLDEV_BBU_OUT_OF_SERVICE
Description BBU out of service.
Cause BBU will not be able to power the cache if ac power fails.
Firmware will switch WriteBack logical drives to WriteThrough.
Action Replace BBU battery.
Address ctl: 0
Severity 2 (Error)
Source InPro
Table 2 RAID Controller Event Codes