User Guide
164 Spheras Storage Director Installation and User Guide
395 Name MLXEV_CTLDEV_POWER_OFF
Description Controller is gone. System is disconnecting from this controller.
Cause The connection to the controller has been lost.
Action None
Address ctl: 0
Severity 0 (Critical)
Source Server
396
Name MLXEV_CTLDEV_POWER_ON
Description Controller powered on.
Cause Controller was removed from the system.
Controller has been powered off.
Action None
Address ctl: 0
Severity 4 (Information)
Source Server
397 Name MLXEV_CTLDEV_ONLINE
Description Controller is online.
Cause New controller has been installed.
Action None
Address ctl: 0
Severity 4 (Information)
Source Server
398 Name MLXEV_CTLDEV_OFFLINE
Description Controller is gone. System is disconnecting from this controller.
Cause Controller was set offline.
Action If you did not expect this, investigate.
Address ctl: 0
Severity 0 (Critical)
Source Server
399 Name MLXEV_CTLDEV_CRITICAL
Description Controller's partner is gone.
Controller is in failover mode now.
Cause Controller was set offline.
Action If you did not expect this, investigate.
Address ctl: 0
Severity 3 (Warning)
Source Server
400 Name MLXEV_CTLDEV_BBU_RECOND_START
Description Battery reconditioning was started.
Cause User started a battery reconditioning.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
401 Name MLXEV_CTLDEV_BBU_RECOND_DONE
Description Battery reconditioning is finished.
Cause Battery reconditioning completed successfully.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
Table 2 RAID Controller Event Codes