© 2003, Adaptec, Inc. 163
388
Name MLXEV_CTLDEV_DEAD
Description Controller is dead. System is disconnecting from this controller.
Cause Hardware failure.
Action Contact your service representative.
Address ctl: 0
Severity 0 (Critical)
Source InP_old
389 Name MLXEV_CTLDEV_RESET
Description Controller has been reset.
Cause Controller received a reset command.
Action If this was an unexpected event, refer to the enclosure manufacturer’s
service manual.
Address ctl: 0
Severity 4 (Information)
Source ExPro InP_old
390 Name MLXEV_CTLDEV_FOUND
Description Controller is found.
Cause New controller has been installed.
Management software has restarted.
System has rebooted.
Action None
Address ctl: 0
Severity 4 (Information)
Source InP_old
391 Name MLXEV_CTLDEV_GONE
Description Controller is gone. System is disconnecting from this controller.
Cause Controller has been powered off.
Controller has been removed from the system.
Action None
Address ctl: 0
Severity 0 (Critical)
Source InP_old
392 Name MLXEV_CTLDEV_BBU_FOUND
Description Battery present.
Cause A battery module has been detected and is now operational.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro InPro
393 Name MLXEV_CTLDEV_BBU_POWER_LOW
Description Battery power low.
Cause Battery power is low.
Action If this message occurs without power failure, replace the battery.
Address ctl: 0
Severity 2 (Error)
Source ExPro InPro
394 Name MLXEV_CTLDEV_BBU_POWER_OK
Description Battery power OK.
Cause Battery has enough power to enable the write data cache.
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro InPro
Table 2 RAID Controller Event Codes