162 Spheras Storage Director Installation and User Guide
338 Name MLXEV_ENCLOSURE_SHUTDOWN
Description Physical disks in enclosure are being spundown.
Cause Enclosure temperature is too high.
Fan failure.
Sensor failure.
Action Turn off the enclosure and repair the problem causing the critical over-
temperature condition.
After the problem is repaired, recover by power cycling the entire
system including the controllers.
Address ctl: 0 enclosure: 13 unit: 14
Severity 1 (Serious)
Source ExPro
339 Name MLXEV_ENCLCOLD_WARN
Description Temperature is below working limit.
Cause Room temperature is too low.
Sensor failure.
Action Inspect the enclosure environment for proper operation and repair as
required.
Increase the room temperature as required.
Address ctl: 0 enclosure: 13
Severity 2 (Error)
Source ExPro
340 Name MLXEV_ENCLCOLD_FAIL
Description Temperature is under safe limit. Failure is imminent.
Cause Room temperature is too low.
Sensor failure.
Action Inspect the enclosure environment for proper operation and repair as
required.
Increase the room temperature as required.
Address ctl: 0 enclosure: 13
Severity 1 (Serious)
Source ExPro
384 Name MLXEV_SYSTEM_STARTED
Description Array management server software started successfully.
Cause The server system (or array management utility server) started.
Action If you did not expect a system reboot, investigate.
Address None
Severity 4 (Information)
Source ExPro InP_old
385 Name MLXEV_CTLDEV_WRITEBACK_ERROR
Description Write back error.
Cause Data cache write failed.
Action The data may have been lost.
Restore the data from a backup.
Address ctl: 0
Severity 2 (Error)
Source InP_old
386 Name MLXEV_CTLDEV_STATE_TABLE_FULL
Description Internal log structures getting full; PLEASE SHUTDOWN AND
RESET THE SYSTEM IN THE NEAR FUTURE.
Cause Too many configuration changes occurred since the last boot.
Action Reboot the system by power cycling when ever convenient.
Address ctl: 0
Severity 3 (Warning)
Source Unspecified
Table 2 RAID Controller Event Codes