332 Name MLXEV_ENCLACCESS_OFFLINE
Description Enclosure access is offline.
Cause Enclosure management connection is broken.
Management hardware failure.
Action Refer to enclosure manufacturer’s service manual.
Address ctl: 0 enclosure: 13
Severity 1 (Serious)
Source ExPro InPro
333 Name MLXEV_ENCLSES_SOFTADDR_OCCURRED
Description Enclosure soft addressing detected.
Cause Enclosure has duplicate loop IDs (soft addressing). Potential data
corruption.
Action Refer to enclosure manufacturer’s service manual.
Address ctl: 0 enclosure: 13
Severity 1 (Serious)
Source ExPro
334 Name MLXEV_ENCLACCESS_READY
Description Enclosure services ready.
Cause –
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
335 Name MLXEV_ENCLHEAT_UNKNOWN
Description Access to temperature sensor has been lost.
Cause Module containing temperature sensor has been removed.
Action None
Address ctl: 0 enclosure: 13 unit: 14
Severity 4 (Information)
Source ExPro
336 Name MLXEV_ENCLPOWER_UNKNOWN
Description Access to power supply status information has been lost.
Cause Module establishing connectivity has been removed.
Action None
Address ctl: 0 enclosure: 13 unit: 14
Severity 4 (Information)
Source ExPro
337 Name MLXEV_ENCLFAN_UNKNOWN
Description Access to fan status information has been lost.
Cause Module establishing connectivity has been removed.
Action None
Address ctl: 0 enclosure: 13 unit: 14
Severity 4 (Information)
Source ExPro