156 Spheras Storage Director Installation and User Guide
258 Name MLXEV_AEMI_FAN_FAILED
Description Fan failure.
Cause Cable connection is broken.
Fan failure.
Action Replace fan.
Address ctl: 0 chn: 13 tgt: 14 Fan: 15
Severity 1 (Serious)
Source InP_old
259
Name MLXEV_FMTFAN_NOTPRESENT
Description Storage cabinet fan is not present.
Cause Enclosure management connection is broken.
Management hardware failure.
Fan is not present.
Action Refer to the enclosure manufacturer’s service manual.
Address ctl: 0 enclosure: 13
Severity 4 (Information)
Source ExP_old InP_old
272 Name MLXEV_FMTPOWER_FAILED
Description Power supply failure.
Cause Broken cable connection.
Power supply failure.
Action Reconnect cable or replace the power supply as required.
Address ctl: 0 enclosure: 13 unit: 14
Severity 1 (Serious)
Source ExP_old InP_old
273 Name MLXEV_FMTPOWER_OK
Description Power supply has been restored.
Cause Faulty power supply has been replaced.
Action None
Address ctl: 0 enclosure: 13 unit: 14
Severity 4 (Information)
Source ExP_old InP_old
274 Name MLXEV_AEMI_PWR_SUPPLY_FAILED
Description Power supply failure.
Cause Broken cable connection.
Power supply failure.
Action Reconnect cable or replace the power supply as required.
Address ctl: 0 chn: 13 tgt: 14 Power Supply: 15
Severity 1 (Serious)
Source InP_old
275 Name MLXEV_FMTPOWER_NOTPRESENT
Description Storage cabinet power supply is not present.
Cause Management connection is broken.
Management hardware failure.
Power supply is not present.
Action Refer to the enclosure manufacturer’s service manual.
Address ctl: 0 enclosure: 13
Severity 4 (Information)
Source ExP_old InP_old
Table 2 RAID Controller Event Codes