User Guide
© 2003, Adaptec, Inc. 155
178 Name MLXEV_SYSDEV_BG_INIT_PAUSED
Description Logical drive background initialization paused.
Cause Background initialization paused due to a higher priority operation.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro
179 Name MLXEV_SYSDEV_BG_INIT_RESTARTED
Description Logical drive background initialization restarted.
Cause Background initialization started after being paused.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro
180 Name MLXEV_SYSDEV_BG_INIT_FAILED
Description Logical drive background initialization failed.
Cause Background initialization failed.
Action None
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro
181 Name MLXEV_SYSDEV_BG_INIT_COMPLETED
Description Logical drive background initialization completed.
Cause Background initialization completed successfully.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro
182 Name MLXEV_SYSDEV_DATA_LOSS_LOW_BBU_CHARGE
Description Low battery charge level. Logical drive may have lost data.
Cause Controller was powered off for duration longer than battery capacity.
User connected a new controller.
User connected a new BBU battery.
Action Run consistency check to verify logical drive consistency.
If needed, restore data from backup.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source InPro
256 Name MLXEV_FMTFAN_FAILED
Description Fan failure.
Cause Cable connection broken.
Fan failure.
Action Replace fan.
Address ctl: 0 enclosure: 13 unit: 14
Severity 1 (Serious)
Source ExP_old InP_old
257 Name MLXEV_FMTFAN_OK
Description Fan has been restored.
Cause Cable is connected properly.
Faulty fan has been replaced.
Action None
Address ctl: 0 enclosure: 13 unit: 14
Severity 4 (Information)
Source ExP_old InP_old
Table 2 RAID Controller Event Codes