User Guide
© 2003, Adaptec, Inc. 153
152 Name MLXEV_SYSDEV_EXPANDCAPACITY_ERROR
Description Expand capacity stopped with error.
Cause Multiple physical disks failed.
Action It may not be possible to recover from this error.
Contact your service representative.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
153 Name MLXEV_SYSDEV_BADBLOCK
Description Bad blocks found.
Cause Bad sector was found on a physical device during consistency check/
rebuild/RAID expansion operation.
Action Run a consistency check with the restore option.
Restore data from a backup.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InP_old
154 Name MLXEV_SYSDEV_SIZECHANGED
Description Logical drive size changed.
Cause A new configuration has been added.
RAID expansion has added extra capacity.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source InP_old
155 Name MLXEV_SYSDEV_TYPECHANGED
Description Logical drive type changed.
Cause A new configuration has been added.
RAID migration completed.
RAID expansion completed on RAID 1.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InP_old
156 Name MLXEV_SYSDEV_BADDATABLOCK
Description Bad data blocks found. Possible data loss.
Cause Bad blocks were found on multiple physical disks in same zone.
Action Restore data from a back up.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source InPro
157 Name MLXEV_SYSDEV_WR_LUN_MAP
Description System drive LUN mapping has been written to configuration.
Cause –
Action None
Address ctl: 0
Severity 4 (Information)
Source ExPro
158 Name MLXEV_SYSDEV_DATAREAD_FROM_BLOCK_IN_BDT
Description Attempt to read data from block that is marked in Bad Data table.
Cause Attempt to read from block that is already marked bad in Bad Data
table. Potential data loss.
Action Restore data from a back up.
Address ctl: 0 logdrv: 15
Severity 1 (Serious)
Source InP_old
Table 2 RAID Controller Event Codes