User Guide
152 Spheras Storage Director Installation and User Guide
146 Name MLXEV_SYSDEV_INIT_CANCELED
Description Logical drive initialization cancelled.
Cause User cancelled the initialization.
Action Restart initialization if required.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
147 Name MLXEV_SYSDEV_INIT_FAILED
Description Logical drive initialization failed.
Cause One/multiple physical device(s) failed.
Controller has been removed.
Controller has been powered off.
Action Refer to the device failure event.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source ExPro InPro
148 Name MLXEV_SYSDEV_FOUND
Description A logical drive has been found.
Cause A new configuration has been added.
MORE completed.
A new controller has been plugged in.
Controller has been powered on.
System has rebooted.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source InPro
149 Name MLXEV_SYSDEV_GONE
Description A logical drive has been deleted.
Cause A new configuration has been added.
A new logical device has been deleted.
Controller has been removed.
Controller has been powered off.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source InPro
150 Name MLXEV_SYSDEV_EXPANDCAPACITY_START
Description Expand capacity started.
Cause User started the online RAID expansion operation.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InPro
151
Name MLXEV_SYSDEV_EXPANDCAPACITY_DONE
Description Expand capacity completed.
Cause Online RAID expansion completed.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InPro
Table 2 RAID Controller Event Codes