User Guide
© 2003, Adaptec, Inc. 151
139 Name MLXEV_SYSDEV_REBUILD_DONE
Description Rebuild on logical drive is over.
Cause Rebuild completed successfully only for this logical drive.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source InPro
140 Name MLXEV_SYSDEV_REBUILD_CANCELED
Description Rebuild on logical drive has been cancelled.
Cause User cancelled rebuild.
Higher priority rebuild started.
Action Restart the rebuild if required.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source InPro
141 Name MLXEV_SYSDEV_REBUILD_ERROR
Description Rebuild stopped with error.
Cause Due to an unknown error on the controller rebuild failed.
Action Try rebuild again.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source InPro
142 Name MLXEV_SYSDEV_REBUILD_NEWDEV_FAILED
Description Rebuild stopped with error. New physical disk failed.
Cause New physical disk failed.
New physical disk is not compatible with MDAC hardware/firmware.
Action Replace the new disk.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source InPro
143 Name MLXEV_SYSDEV_REBUILD_SYSDEV_FAILED
Description Rebuild stopped because logical drive failed.
Cause At least one more physical device failed in the array.
Action It may not be possible to recover from this error.
Contact your service representative.
Address ctl: 0 logdrv: 15
Severity 2 (Error)
Source InPro
144 Name MLXEV_SYSDEV_INIT_STARTED
Description Logical drive initialization started.
Cause User started the initialization. Any previous data are lost.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InPro
145 Name MLXEV_SYSDEV_INIT_DONE
Description Logical drive initialization finished.
Cause Initialize operation completed successfully.
Action None
Address ctl: 0 logdrv: 15
Severity 4 (Information)
Source ExPro InPro
Table 2 RAID Controller Event Codes